Product Description
Tested on a wide range of wooden doors, achieving 60 minutes integrity and either 30 or 60-minute fire protection and insulation according to BS476 Part22.
Up to 60 minutes fire protection achieved on open joists and floorboards according to BS476 Part 20.
90-minute fire rating achieved on timber mouldings and carcasses according to BS476 Part 20.
Product Performance
Tested on a range of timber types, including plywood and MDF, complying with BS476 Parts 6 & 7, Classes 0 & 1 (Spread of Flame).
Tested to European Standard EN1364-1, achieving 66 minutes integrity.
Complies with Classification B/S1/d0 of European Standard EN13823, single burn test (SBI) and EN11925-2 (ignitability).
Data Files and Downloads
Related Products
Envirograf HWAP/WB Primer is a clear water based primer for use under Envirograf HW01 and HW02E Int...